Description

A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.



HIGH: 7.8CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
HIGH: 8.5CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')

Product status

Default status
unknown

Any version before V3.2 HF1
affected

References

https://cert-portal.siemens.com/productcert/html/ssa-868282.html