Assigner | siemens |
Reserved | 2024-04-16 |
Published | 2024-05-14 |
Updated | 2024-06-06 |
Description
A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.208), Parasolid V36.1 (All versions < V36.1.173). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Problem types
Product status
Any version before V35.1.256
Any version before V36.0.208
Any version before V36.1.173
References
https://cert-portal.siemens.com/productcert/html/ssa-046364.html