We use these services and cookies to improve your user experience. You may opt out if you wish, however, this may limit some features on this site.

Please see our statement on Data Privacy.

Crisp.chat (Helpdesk and Chat)

Ok

THREATINT
PUBLISHED

CVE-2024-10313

iniNet Solutions SpiderControl SCADA PC HMI Editor Path Traversal



Description

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.

Reserved 2024-10-23 | Published 2024-10-24 | Updated 2024-10-24 | Assigner icscert


HIGH: 8.0CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

HIGH: 8.6CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Problem types

CWE-22 Path Traversal

Product status

Default status
unaffected

8.10.00.00
affected

Credits

elcazator from ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity, Inc. reported this vulnerability to CISA. finder

References

www.cisa.gov/news-events/ics-advisories/icsa-24-298-02

cve.org (CVE-2024-10313)

nvd.nist.gov (CVE-2024-10313)

Download JSON

Share this page
https://cve.threatint.com/CVE/CVE-2024-10313

Support options

Helpdesk Chat, Email, Knowledgebase
Telegram Chat
Subscribe to our newsletter to learn more about our work.