A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.
In Tenda AC8 16.03.34.06 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion compare_parentcontrol_time der Datei /goform/saveParentControlInfo. Durch Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung.
2024-10-18: | Advisory disclosed |
2024-10-18: | VulDB entry created |
2024-10-18: | VulDB entry last update |
minipython (VulDB User)
vuldb.com/?id.280915 (VDB-280915 | Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow)
vuldb.com/?ctiid.280915 (VDB-280915 | CTI Indicators (IOB, IOC, IOA))
vuldb.com/?submit.421340 (Submit #421340 | Tenda AC8v4 V16.03.34.06 Stack-based Buffer Overflow)
github.com/...b/main/ac8v4/compare_parentcontrol_time_vul.md