Assigner | siemens |
Reserved | 2023-07-19 |
Published | 2023-08-08 |
Updated | 2024-06-11 |
Description
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C | |
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N |
Problem types
CWE-476: NULL Pointer Dereference
Product status
Any version before V34.1.258
Any version before V35.0.254
Any version before V35.1.171
Any version before V14.1.0.11
Any version before V14.2.0.6
Any version before V14.3.0.3
References
https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf
https://cert-portal.siemens.com/productcert/html/ssa-407785.html